Reports

Reports are text files with data summarizing results over all runs, e.g. parameter sweep, temperature sweep and worst case re-runs. 

Report creation is accessed from  the "File\Reports" main menu item. Reports can be viewed in the internal text viewer/editor from the "View\Reports" main menu items. If the file does not exist, the "View\Reports" reports selection will also create the file.

DC Operating Point Report

Contains the maximum and minimum values of all DC operating node voltages and currents out of all runs.

This report is typically used to determine the worst case dc operating voltages and currents of a design at a constant supply voltage.

DC Sweep Report

Contains the maximum and minimum values of all node voltages and currents out of all runs, over the DC sweep range. It may be required  to restrict the sweep range in the simulation to that being examined. For example, in examining a regulator, the sweep should be set to sweep over the valid operating conditions of the regulator, not from 0V.

This report is typically used to determine the worst case dc operating voltages and currents of a design when a supply voltage is varied.

AC Sweep Report

Contains the maximum and minimum values of all node voltages and currents out of all runs, over the AC sweep range.

Contains  the maximum and minimum values of all Loop Gain data if Loop gain data has been enabled in the AC setup dialog.

Pulse Analysis

Contains the maximum and minimum values of  pulse data over all runs. Pulse setup is via the Setups menu. 

Transient Power

This report contains a list of component transient powers for all runs.

Noise Report

Contains an ordered list of individual device noise at specified frequencies.

Contents